USEPA method 5 - Determination of particulate emissions from stationary
sources. Principle particulate matter is withdrawn isokinetically from the
source and collected on a glass fibre filter maintained at temperature range of
120+-14oC or such other temperature as specified by an applicable
subpart of the standard or approved by the administrator, US Environmental
Protection Agency, for a particular application. The particulate mass, which
includes any material that condenses at or above the filtration temperature, is
determined gravimetrically after he removal of uncombined water. This Method is
applicable for the determination of particulate emissions from stationary
sources |
|